Online Analyzers

Online Analyzers

Product Details:

X

Product Description

gaZpro Ox Online Analyzer

Control Card

Solid State Electronics Base

Range

Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)

Resolution

Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)

Display

3 Digit LED

Size

Standard Enclosure Size: H: - 200 mm W: - 180mm D: - 320 mm

Oper. Temperature

0 50 deg C

Visual Indication

A) Pilot B) Warn C) Alarm

Controls

Optional: - A) Reset B) Accept

Parameter Setting

A) Zero B) Span C) Warn D) Alarm

Input Signals

Standard: - 4 20 mA.


Optional: - 0 1 Vdc

Outputs

Standard: - 4 20mA. Recorder Output, Potential free Relay contacts for Alarms. Optional: - Repeater output for Alarms, 0 1 vDC. Recorder Output

Power Supply

Standard: - 220 vAC. 50 Hz


Optional: - 110 vAC. 50 Hz

Mounting

Standard: Panel Mounting

Mounting

Standard: Panel Mounting

Flow

100 200 ml / min.

Pressure

Gas Pressure on Sensor head should not exceed 1 Kg. / cm2

Connections

Standard: - NPT for 1/P and O/P


Optional: - As per specifications

Sensor Type

Electrochemical

Sensor Life

Max. 2 years (in fresh air)

Response Time

90% of FSD in <30 Sec.

gaZpro Ox - FLP Online Analyzer

Control Card

Solid State Electronics Base

Range

Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)

Resolution

Depends on sensor (ppm level for O2 in H2 & % or ppm level for O2 In N2)

Display

3 Digit LED

Size

Standard Enclosure Size: H: - 200 mm W: - 180mm D: - 320 mm

Oper. Temperature

0 50 deg C

Visual Indication

A) Pilot B) Warn C) Alarm

Controls

Optional: - A) Reset B) Accept

Parameter Setting

A) Zero B) Span C) Warn D) Alarm

Input Signals

Standard: - 4 20 mA.


Optional: - 0 1 Vdc

Outputs

Standard: - 4 20mA. Recorder Output, Potential free Relay contacts for Alarms. Optional: - Repeater output for Alarms, 0 1 vDC. Recorder Output

Power Supply

Standard: - 220 vAC. 50 Hz


Optional: - 110 vAC. 50 Hz

Mounting

Standard: Panel Mounting

Mounting

Standard: Panel Mounting

Flow

100 200 ml / min.

Pressure

Gas Pressure on Sensor head should not exceed 1 Kg. / cm2

Connections

Standard: - NPT for 1/P and O/P


Optional: - As per specifications

Sensor Type

Electrochemical

Sensor Life

Max. 2 years (in fresh air)

Response Time

90% of FSD in <30 Sec.

Hazardous Protection

Explosion proof version for application in IIA/IIB, IIC



Enter Buying Requirement Details
Email Id
Mobile number


Back to top
trade india member
POLLUTION PROTECTION SYSTEM MUMBAI PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.